![]() | How can I remove dust, marks or fingerprints from the surface of the filter? |
![]() |
Use a soft cloth (micro-fiber 70% polyester and 30% polyamide) or the black protective sock that wraps the filter. Do not use paper, abrasive sponges, detergents or alcohol. |
![]() | I am not able to start the pump using the priming button. |
![]() |
|
![]() | The pre-filter lid doesn't close |
![]() |
Check that pre-filter handles are properly aligned in the “lock” position |
![]() | I can't insert the AQUASTOP valve into the filter top. |
![]() |
|
![]() | I can't remove the AQUASTOP |
![]() |
The AQUASTOP release lever hasn't been lifted. |
![]() | I have turned the lock nuts of the AQUASTOP or the Cross Rim assemblies so much that they have fully come off. |
![]() |
Replace the lock nuts by turning them clockwise so they screw back down onto the AQUASTOP or Rim Connectors. |
![]() | I'm not able to pull out the mechanical pre-filter and chemical cartridges. |
![]() |
The knob has not been completely turned to the un-lock position. Be sure to turn the knob fully counter-clockwise to remove the cartridges. The power has not been removed from the filter causing suction on the cartridge. Make sure to remove the power before performing any maintenance procedures. |
![]() | I'm not able to close the four metal lid fasteners. |
![]() |
|
![]() | I'm not able to close the four metal lid fasteners. |
![]() |
The filter head is not correctly oriented with respect to the filter body. Not all four metal lid fasteners are fully inside their seats. Assure that all the metal lid fasteners are simultaneously wide open before proceeding with filter head closing operation. |
![]() | I'm not able to disengage the filter head from the filter canister. |
![]() |
Assure that all the four silver metal lid fasteners are simultaneously wide open. The presence of foreign objects could have generated an anomalous friction. Take off the filter head by simultaneously pulling the appropriate handles (there could be the need of another person helping you). After that, proceed with filter gasket cleaning. Important: The motor head could get stuck if you try to remove it by pulling one side only. Remove the filter head by pulling with both hands on the proper grip points. |
![]() | The mechanical cartridge clogs too early. |
![]() |
The mechanical cartridge is a high efficiency by-pass-free filter. For this reason everything that is captured by the filter remains trapped in it. The mechanical filter has been designed so that there is a water flow reduction of 15 l/h per day in a mature and average charged aquarium.
An early clogging could be caused by:
|
![]() | Air bubbles continuously come out from filter output. |
![]() |
|
![]() | After switching off and on of the filter, the filter is On and the flow rate is zero or insufficient. |
![]() |
An air bubble could be trapped inside the impeller chamber. By acting on the priming button, the operation's conditions previous to the power being off are restored. If the mechanical pre-filter is very dirty (low flow), even the use of the priming button could not be sufficient to solve the problem. In this case clean the mechanical pre-filter cartridge. |
![]() | After having switched off the unit and cleaned the mechanical pre-filter, the filter is On but flow rate is zero or insufficient. |
![]() |
An air bubble could be trapped inside the impeller chamber. By operating the priming button, the normal operation of the unit can be restored. |
![]() | After cleaning, max flow rate condition (fully white flow graph) is not restored. |
![]() |
The system measures the water flow by reading the electrical parameters of the pump, and it has been calibrated by referring to a standard application, i.e. intake and output hoses of the same length 1,5m, telescopic stem + strainer + regular cross rim device at intake, twin nozzles + regular cross rim device at output and AQUASTOP valve fully open. Different configurations may introduce different hydraulic circuit losses and consequently delay or accelerate the indication of flow reduction. A too early water flow reduction may be also caused by:
|
![]() | When removing the filter head from the unit, water comes out from the metal locking levers |
![]() |
In order to avoid water spilling when cleaning, during normal operation, the filter unit is not completely full of water, but it maintains an air chamber underneath the filter head to keep water inside at such a level so that it does not overflow. During normal operations of cartridges opening or AQUASTOP disengagement, water level inside tends to rise. Wrong operations may cause water to spill and to gather inside the unit head. The cartridge cups also serve the purpose by removing some water from the unit during maintenance operation, and thus restoring the adequate water level. Wrong operations not to perform include:
|
![]() | There is water under filter canister feet. |
![]() |
|
![]() | The conductivity graph shows sudden drops. |
![]() |
The conductivity reading is only precise and stabilized after 24-48 hours of filter operation.Variations may be due to:
|